MACHINE ENERGY & HEALTH MONITOR
Is the machine healthy, producing, and using energy well?
McMonitor is a compact, ruggedised unit that turns any production machine into a connected, self-reporting asset. Mounted at the machine, it continuously measures electrical energy, temperature, running speed and machine state — shows them on a local touchscreen and web dashboard, records them to on-board storage, and forwards them to the cloud. One trustworthy view of how each machine is really performing, for operator, supervisor and plant manager alike.
One firmware, any machine. Parameters, sensors and thresholds are set in a simple on-device configuration — a new machine is commissioned by editing configuration, not re-programming.

One device, three questions answered
Is the machine healthy? Is it producing? How much energy is it consuming — and is that energy being used productively?
Electrical monitoring
Full 3-phase or single-phase metering: voltage, current, power factor, kW / kVA / kVAR, frequency, energy.
Thermal monitoring
Up to 8 analog inputs — RTD and thermocouple (J/K/R/S/T) — plus ambient reference.
Productivity
Machine run / idle / break state, runtime, RPM, shift-wise accounting, stoppage analysis.
Health & events
Automatic detection of electrical faults, sensor faults, stalls, stoppages and abnormal conditions.
Visibility
Local colour touchscreen + responsive web dashboard, live and historical.
Connectivity
Wi-Fi, MQTT and HTTP cloud integration, on-board SD logging.
TECHNICAL SPECIFICATIONS
Built for the shop floor
PLATFORM & PROCESSING
| ITEM | SPECIFICATION |
|---|---|
| Controller | Industrial dual-core 32-bit processor, industrial temperature grade |
| Configuration | On-device configuration — parameters, sensors, thresholds; no firmware change to commission |
| Storage | On-board SD card for data and event logs; non-volatile storage for settings and event history |
| Real-time clock | Battery-backed — accurate time-stamping maintained across power cycles |
| Firmware update | Over-the-air (OTA) capable |
ELECTRICAL MEASUREMENT (VIA MODBUS ENERGY METER)
| PARAMETER | DETAIL |
|---|---|
| Interface | Modbus RTU (RS-485) or Modbus TCP/IP |
| Phases | Single-phase or three-phase (auto-detected or configured) |
| Measured | Voltage (per phase), current (per phase), power factor, kW, kVA, kVAR, frequency, energy |
| Compatibility | Configurable per parameter — supports a wide range of energy meters and formats |
| Display slots | Up to 24 electrical parameters |
ANALOG / THERMAL INPUTS
| PARAMETER | DETAIL |
|---|---|
| Channels | 8 universal analog inputs + ambient (cold-junction) reference |
| Sensor types | RTD, thermocouple J / K / R / S / T, 0–100 mV |
| Interface | RS-485, non-blocking acquisition (no impact on the control loop) |
| Per channel | Type, scaling, name and alarm limits individually configurable |
| Diagnostics | Open-sensor detection (broken wire) and uncalibrated-reading flagging |
DIGITAL INPUTS & SPEED
| PARAMETER | DETAIL |
|---|---|
| Digital inputs | Up to 4 — machine run signal, break, general-purpose events |
| Polarity / debounce | Active-high or active-low, debounce configurable per input |
| Speed (RPM) | Pulse / tacho input, period-timing measurement, configurable pulses-per-revolution |
DISPLAY, INTERFACE & CONNECTIVITY
| ITEM | SPECIFICATION |
|---|---|
| Local display | Colour touchscreen — live values, status, settings and event history |
| Web dashboard | Built-in responsive web UI — live + historical, day / night theme, from phone or PC |
| Network | Wi-Fi (STA with AP fallback for commissioning) |
| Cloud | MQTT (encrypted) and HTTP — device registration, telemetry, remote configuration |
| On-site setup | Wi-Fi access-point mode for browser-based commissioning; no laptop software required |
KEY FEATURES
What sets McMonitor apart
One firmware, any machine
Every parameter, sensor, threshold and display slot is in a simple on-device configuration — commission by editing configuration, not rewriting firmware. A companion builder generates valid setups.
Fail-safe by design
A bad or partial configuration can never disable the unit. It validates on load, keeps a known-good backup, and always brings up its network and web interface — so a corrected configuration can be uploaded remotely.
Productivity & OEE accounting
Run / idle / break state (debounced), shift-wise runtime accounting, stoppage capture with an auto-inferred reason, and micro-stop vs true-downtime separation — the availability half of OEE, made honest.
Energy intelligence
Beyond metering: energy is related to production, exposing idle-energy waste, power-factor penalties and demand peaks — energy spend tied to actual output, not just measured.
Local + remote, always in sync
Touchscreen and web dashboard are two views of one device — a setting changed on the screen is the setting the web shows. Live values, historical trends and the event log on both.
Secure, resilient connectivity
Encrypted MQTT and HTTP with server-driven registration. Data logs to SD regardless of connectivity, so a network outage never loses data.
INTELLIGENT EVENT & ALARM SYSTEM
It doesn’t just show numbers — it interprets them
A unified event engine watches every signal and raises a time-stamped event the moment something meaningful happens — routed to the on-screen log, the web dashboard, on-board storage and the cloud at once. Events survive power cycles, so the history before any incident is preserved. Events serve three purposes: predict breakdowns, maximise uptime, manage energy.
OPERATIONAL & PRODUCTIVITY EVENTS AVAILABLE
| EVENT | PURPOSE |
|---|---|
| Machine ON / OFF | Track every start and stop |
| Break start / end | Planned-break accounting |
| Shift start / over | Shift boundaries with runtime / idle / break summary |
| Stoppage start / end | Duration + auto-inferred reason (break / gap / fault / unclassified) |
| Minor-stop vs downtime | Micro-stop detection separate from true downtime |
| RPM stall | Machine running but shaft not turning — belt break, jam, locked rotor |
| Communication lost / restored | Meter or sensor link health |
| Power-on / boot | Detect unexpected restarts, with configuration-source record |
ELECTRICAL & SENSOR-HEALTH EVENTS AVAILABLE
| EVENT | DETECTS |
|---|---|
| Phase loss | A supply phase dropping while others remain (three-phase) |
| Phase imbalance | Voltage or current imbalance across phases beyond a set limit |
| Over- / under-voltage | Sustained supply excursions that stress and shorten motor life |
| Over-current | Overload conditions |
| Over-speed | Shaft speed beyond a safe configured limit |
| Sensor fault | Open thermocouple / RTD (broken wire) and uncalibrated readings |
| Channel alarm set / clear | Any monitored value crossing its configured limit |
PREDICTIVE & ENERGY-ANALYTICS EVENTS ROADMAP
Analytical events that build on the same engine and each machine’s own operating history.
| EVENT | PREDICTIVE VALUE |
|---|---|
| Energy per shift / per day | Energy consumption tied to each shift’s output |
| Idle-energy waste | Energy consumed while running but not producing — a key efficiency KPI |
| Peak-demand alert | Demand approaching a contracted or penalty threshold |
| Power-factor penalty | Sustained low PF that attracts utility penalties |
| Current / load drift | Rising running current vs learned baseline — bearing wear, friction |
| Power-factor decline trend | Gradual motor degradation |
| Baseline learning | The unit learns each machine’s normal, then flags departures |
AVAILABLE shipping in current firmware · ROADMAP designed on the same event engine, delivered in a subsequent release.
APPLICATIONS
Any electrically-driven machine where uptime, energy and condition matter
Machining & metalworking
CNC, lathes, presses, grinders — runtime, spindle speed, motor load and stoppage capture.
Plastics & rubber
Injection moulding, extrusion — barrel / zone temperatures via thermocouples plus energy per cycle.
Textiles
Motor health, running speed, shift-wise production and downtime accounting.
Food, pharma & process
RTD temperature monitoring, energy metering and event logging for traceability.
Pumping, HVAC & utilities
Motor condition, power factor, phase health and energy on critical rotating equipment.
General manufacturing
Any machine where an OEE / availability picture and energy visibility are wanted without a full SCADA rollout.
INDUSTRY BENEFITS
Why it pays for itself
From a machine that just runs — to one that tells you its health, its output and its energy, every minute.
Machine Monitor (McMonitor) is configured to each machine — parameters, sensors, thresholds and display are set on-device. “Available” features ship in the current firmware; “roadmap” analytics are built on the same event engine and delivered in a subsequent release. Electrical measurement is via a Modbus energy meter. Contact KVAR Technologies for a demonstration and a configuration matched to your machines.
NEXT STEP
Put a Machine Monitor on your line
- Tell us the machine, its energy meter and the sensors you want watched
- We prepare an on-device configuration and a live demo at your machine
- Commission in the browser — value at the machine on day one, cloud when you want it