ENVIRONMENTAL COMPLIANCE MONITORING
Measure it. Prove it. Stay compliant.
Continuous monitoring for air quality, stack emissions, dust, cathodic protection and temperature — the sensor on the boundary, the logger in the panel, the display at the gate and the compliance record in the office, from one team. Every solution comes in Basic, Advanced and Premium editions, and can run standalone, on-premise or fully on the cloud.
Buy the hardware, add the compliance software, or take the integrated cloud — start anywhere, grow when you are ready.

One partner, from the sensor to the signed report
Five monitoring areas, one platform. Each is a complete solution on its own, and every one can start as hardware alone and grow into a connected, compliance-ready system.
Air Quality (AQI)
PM2.5, PM10, gases, weather — ambient and boundary.
Stack / Chimney
Emission gases, flow and temperature at the stack.
Dust
SPM / RSPM ambient dust at site and boundary.
Cathodic Protection
Pipe-to-soil potential and current on pipelines.
Temperature
Process, cold-room and boiler temperature & humidity.
Who it is for
Any operation that has to measure its environmental footprint and prove it to a regulator, a customer or a court.
Three deployment options
The same solution, delivered the way that fits your site and your IT.
Hardware & on-premise
Sensors, loggers, interruptors and displays running on your own site — local logging, alarms and reports, no subscription.
Compliance software
The reporting and alerting layer on top of your data — on KVAR devices or the instruments you already have.
Integrated cloud
The whole chain connected — devices, dashboards, compliance reports and a live feed to the authority.
Air quality — in the field
The outdoor board, the sensor-to-cloud chain, and the live web dashboard behind it.

The complete solution — sensors → AQM data logger → LED display → cloud server & web dashboard, with builder and manager logins.
Field to cloud — field install with PM2.5 / PM10 / temp / humidity sensors and AQM logger, data over GSM / 4G / Wi-Fi / LAN, and per-site vs all-sites dashboards.
Remote environment monitoring — PM2.5, PM10, temperature, humidity and AQI on a board in the pharma area, with live and historical data on web and mobile.
Temperature & humidity monitoring
Large-digit temp / humidity displays with high / low set-points and instant e-mail / SMS alerts — for server rooms, clean rooms, warehouses, pharma and cold rooms.



WHAT WE MONITOR
Five environmental parameters, one way of working
Every parameter is sensed, logged, shown and reported the same way — so the plant learns one system, not five.
Air Quality (AQI)
Ambient and boundary air quality — PM2.5, PM10, CO2, NO2, SO2, CO, plus temperature, humidity and wind. Minute data to the cloud, a public AQI board at the gate, and a live feed to the municipal body.
Hardware: ambient air-quality sensor suite · logger · AQI display board.
Stack / Chimney
Continuous emission monitoring at the stack — SPM, SO2, NOx, CO, flow and stack temperature. Values logged against time, shown on a parameter board and rolled into the emission-compliance report.
Hardware: stack sensors / analyser interface · logger · parameter display.
Dust
Ambient dust at the site and along the boundary — SPM and RSPM logged continuously, with a display at the source and an alert the moment dust climbs past the set level.
Hardware: dust sensor · logger · display · optional siren.
Cathodic Protection (CP)
Continuous cathodic-protection monitoring on buried pipelines and tank farms. Remote CP loggers record pipe-to-soil potential at each test post; a synchronised interruptor (timer) switches the current on and off so IR-free readings can be taken across the whole survey without a technician at every station.
Hardware: CP data logger + current interruptor (timer) · test-post interface.
Temperature
Process, cold-room and boiler temperature and humidity, logged continuously with alarm relays and alerts on excursion — the live warning and the audit record from the same instrument.
Hardware: RTD / thermocouple sensors · logger · large temperature display.
HARDWARE
Sensors, loggers, interruptors and displays
Built like shop-floor equipment — rugged, configurable, and specified to the parameter, the channel count and the viewing distance you need.
Data loggers — KV2020 Series
- 1 to 64 channels — from a single panel logger to a full-plant record
- Universal inputs: RTD, thermocouple, mV, mA, 4–20 mA, voltage and current
- On-board memory, SD-card logging and periodic e-mail reports
- Panel, DIN or wall mount; compact hide-anywhere and outdoor IP-rated variants
CP loggers & current interruptors
- Remote CP data logger at each test post — pipe-to-soil potential and current
- Synchronised current interruptor (timer) for IR-free on/off potential surveys
- GPS time synchronisation across the line; solar / battery option
- Reports to the cloud for continuous, unattended monitoring
Sensors
- Air quality: PM2.5, PM10, CO2, NO2, SO2, CO, temperature, humidity, wind
- Stack / emission gas and flow; ambient dust (SPM / RSPM)
- Temperature & humidity: RTD, thermocouple, digital T/H probes
- IP-rated enclosures for outdoor, boundary and stack mounting
Displays — any size, indoor or outdoor
Large LED boards sized to the throw distance, showing live values, parameter names and units. Range, size, viewing distance and environment:
| PANEL SIZE | BEST FOR | VIEWING DISTANCE | INDOOR / OUTDOOR | WEATHER RATING |
|---|---|---|---|---|
| 2 × 3 ft | Control room, gate lobby, indoor location | up to ~20 m | Indoor | Standard enclosure |
| 3 × 4 ft | Shop floor, boundary wall | up to ~40 m | Indoor / covered | Splash-resistant |
| 4 × 6 ft | Public / gate AQI board, outdoor boundary | up to ~70 m | Outdoor | IP-rated, weatherproof, sunlight-readable |
| Custom | Built to your parameter list & viewing distance | To specification | Indoor or outdoor | To specification |
Digit height, brightness and number of parameter rows are configured to the size and the reading distance. Outdoor boards are sunlight-readable and IP-rated for rain and dust.



Alarms & buzzers
- Audible buzzer and tower / beacon lamp on threshold breach
- Relay outputs to drive sirens, gates or plant equipment
- Wired alongside the logger — local warning without waiting for the cloud
EDITIONS & SOFTWARE
Basic, Advanced, Premium — set in software, not in the box
Every solution ships in three editions. They are software feature-gates, so a site can start on Basic and move up without changing the instrument on the wall.
BASIC
See it and log it
Continuous logging, a live display and configurable local alarms, with e-mail alerts on a breach. The proof starts the day it is installed.
ADVANCED
Report it and prove it
Adds the web dashboard, automatic compliance reports (daily, shift and exceedance), trend analytics and role-based login — the reporting and accountability layer.
PREMIUM
Connect it and scale it
Adds the cloud, multi-site roll-up, ERP / SCADA integration, the public display board and a live feed to the authority, with long retention and a full audit trail.
| CAPABILITY | BASIC | ADVANCED | PREMIUM |
|---|---|---|---|
| Continuous logging & local display | ✓ | ✓ | ✓ |
| Configurable thresholds & local alarm | ✓ | ✓ | ✓ |
| E-mail alerts | ✓ | ✓ | ✓ |
| SMS / WhatsApp alerts (at provider cost) | OPT | OPT | OPT |
| Web dashboard | – | ✓ | ✓ |
| Automatic compliance reports (Excel / PDF) | – | ✓ | ✓ |
| Report types — daily, shift, exceedance, statutory | – | ✓ | ✓ |
| Trend & exceedance analytics | – | ✓ | ✓ |
| Login levels | Single | Role-based | Role-based + escalation |
| Cloud — minute data, 24×7 | – | OPT | ✓ |
| Multi-site / multi-location | – | – | ✓ |
| ERP / SCADA integration (API) | – | OPT | ✓ |
| Public display board & live authority feed | – | OPT | ✓ |
| Long retention & full audit trail | – | ✓ | ✓ |
✓ included OPT optional add-on – not in this edition.
Connectivity, integration & access
Connectivity & protocols
RS232 / RS485 (Modbus RTU), Modbus TCP / Ethernet, 4–20 mA, Wi-Fi, GPRS / 4G, USB and SD.
Works with your ERP
Feeds your existing ERP, SCADA or the authority portal by REST API or scheduled export — no rip-and-replace.
Configurable thresholds
High/low limits per parameter are configuration, not code, and change without a site visit.
Login levels & escalation
Operator, supervisor and admin roles; alerts escalate through defined levels if a breach is not addressed in time.
OPTIONS & PRICING
Available in several options — take the part you need
Every solution is available as hardware, as compliance software, or as the whole integrated cloud. Each upgrades cleanly into the next, because the hardware and software are built together.
OPTION 01
Hardware
- Sensors, loggers, CP interruptors and displays
- Configurable thresholds and local alarms on the device
- Standard protocols — wire it into your own system
- Local logging and reports without any subscription
For plants that run their own SCADA / historian and just need reliable instruments.
OPTION 02
Compliance software
- Runs on KVAR devices or the instruments you already have
- Automatic compliance reports and exceedance alerts
- Role-based login and timed escalation
- On-premise or cloud; export to Excel, PDF, ERP or authority portal
For sites that have the sensors but need the reporting and accountability layer.
OPTION 03
Integrated cloud
- The whole chain connected — devices to dashboard to report
- Minute data to the cloud, 24×7, across every site
- Public display board and live API feed to the authority
- Long retention and a full audit trail
For mandated and multi-site programmes that need continuous, verifiable monitoring.
Indicative price ranges
Price depends on the option and the features selected — channels, parameters, display size and range, number of users and login levels, and the edition. Indicative starting ranges:
LOGGERS
₹8K – 45K
Per logger, by channel count, input types and connectivity.
DISPLAYS
₹12K onwards
By panel size, digit height, range and indoor / outdoor build.
SOFTWARE
Basic from ₹3L
By users, login levels, sites and edition (Basic / Advanced / Premium).
Sensors, CP interruptors, alarms and installation are quoted to the site. Figures are indicative starting points for budgeting; a firm quotation is prepared against your requirement.
Return on investment
The system pays for itself the first time it keeps you compliant — and every day it saves the manual work of proving it.
From a reading on a sensor — to a report you can hand to the inspector.
KVAR Technologies environmental compliance range. Parameters, sensors, editions and display sizes are configured to the application; prices are indicative starting ranges for budgeting and are refined at proposal stage. Product photographs shown where available; remaining items to be added. Contact KVAR Technologies for a configuration and quotation matched to your site.
NEXT STEP
From the sensor to the signed report
- Tell us the parameter, the limits and whether it is for a regulator, a customer or your own record
- We specify sensors, logger, display and edition — and a report format the authority will accept
- Start with hardware or the full integrated cloud — and scale across sites when you are ready
Phone: 022 6899 0651-52 · 7506 059922 · Email: sales@kvartech.com
www.kvartech.com · Future-ready. Today.