KVARSince 1988
Environmental ComplianceMONITORING · REPORTING · COMPLIANCE

ENVIRONMENTAL COMPLIANCE MONITORING

Measure it. Prove it. Stay compliant.

Continuous monitoring for air quality, stack emissions, dust, cathodic protection and temperature — the sensor on the boundary, the logger in the panel, the display at the gate and the compliance record in the office, from one team. Every solution comes in Basic, Advanced and Premium editions, and can run standalone, on-premise or fully on the cloud.

Buy the hardware, add the compliance software, or take the integrated cloud — start anywhere, grow when you are ready.

Outdoor air-quality display at a plant gate
Measured at the boundary. A public AQI board, streaming to the cloud every minute.

One partner, from the sensor to the signed report

Five monitoring areas, one platform. Each is a complete solution on its own, and every one can start as hardware alone and grow into a connected, compliance-ready system.

Air Quality (AQI)

PM2.5, PM10, gases, weather — ambient and boundary.

Stack / Chimney

Emission gases, flow and temperature at the stack.

Dust

SPM / RSPM ambient dust at site and boundary.

Cathodic Protection

Pipe-to-soil potential and current on pipelines.

Temperature

Process, cold-room and boiler temperature & humidity.

Who it is for

Any operation that has to measure its environmental footprint and prove it to a regulator, a customer or a court.

Cement & Building MaterialsSteel & MetalsChemicals & FertilizersPower & EnergyPharma & Life SciencesOil & Gas / PipelinesInfrastructure & ConstructionMunicipal & GovernmentPorts, Mining & LogisticsTextiles & Processing

Three deployment options

The same solution, delivered the way that fits your site and your IT.

1
Hardware & on-premise

Sensors, loggers, interruptors and displays running on your own site — local logging, alarms and reports, no subscription.

2
Compliance software

The reporting and alerting layer on top of your data — on KVAR devices or the instruments you already have.

3
Integrated cloud

The whole chain connected — devices, dashboards, compliance reports and a live feed to the authority.

Air quality — in the field

The outdoor board, the sensor-to-cloud chain, and the live web dashboard behind it.

Outdoor air-quality monitoring LED display board at a plant gate
Outdoor air-quality display. A weatherproof LED board showing CO₂, NO₂, PM2.5, PM10 and AQI at the gate; for industrial areas, construction, smart cities, highways and mining.

The complete solution — sensors → AQM data logger → LED display → cloud server & web dashboard, with builder and manager logins.

Field to cloud — field install with PM2.5 / PM10 / temp / humidity sensors and AQM logger, data over GSM / 4G / Wi-Fi / LAN, and per-site vs all-sites dashboards.

Remote environment monitoring — PM2.5, PM10, temperature, humidity and AQI on a board in the pharma area, with live and historical data on web and mobile.

Temperature & humidity monitoring

Large-digit temp / humidity displays with high / low set-points and instant e-mail / SMS alerts — for server rooms, clean rooms, warehouses, pharma and cold rooms.

Temperature and humidity monitoring, how it works
How it works. Set the range, continuous monitoring, out-of-range continuous alarm, e-mail / SMS alerts, and auto-reset when back to normal.
Server room temperature and humidity display
Server room / data centre. Temperature and humidity read at a glance outside the room.
Pharma clean room temperature and humidity monitoring
Pharma clean room. Compliant temperature and humidity monitoring at the door.

WHAT WE MONITOR

Five environmental parameters, one way of working

Every parameter is sensed, logged, shown and reported the same way — so the plant learns one system, not five.

Air-quality monitoring display board

Air Quality (AQI)

Ambient and boundary air quality — PM2.5, PM10, CO2, NO2, SO2, CO, plus temperature, humidity and wind. Minute data to the cloud, a public AQI board at the gate, and a live feed to the municipal body.

PM2.5 / PM10GasesWeatherCPCB-alignedPublic board

Hardware: ambient air-quality sensor suite · logger · AQI display board.

Stack emission parameter display board

Stack / Chimney

Continuous emission monitoring at the stack — SPM, SO2, NOx, CO, flow and stack temperature. Values logged against time, shown on a parameter board and rolled into the emission-compliance report.

SPMSO2 / NOx / COFlowStack temperatureCEMS-ready

Hardware: stack sensors / analyser interface · logger · parameter display.

Ambient dust monitor

Dust

Ambient dust at the site and along the boundary — SPM and RSPM logged continuously, with a display at the source and an alert the moment dust climbs past the set level.

SPM / RSPMBoundaryThreshold alertsContinuous log

Hardware: dust sensor · logger · display · optional siren.

Cathodic protection data logger

Cathodic Protection (CP)

Continuous cathodic-protection monitoring on buried pipelines and tank farms. Remote CP loggers record pipe-to-soil potential at each test post; a synchronised interruptor (timer) switches the current on and off so IR-free readings can be taken across the whole survey without a technician at every station.

Pipe-to-soil potentialCurrentSynchronised interruptor / timerGPS time syncSolar option

Hardware: CP data logger + current interruptor (timer) · test-post interface.

Large temperature and humidity display

Temperature

Process, cold-room and boiler temperature and humidity, logged continuously with alarm relays and alerts on excursion — the live warning and the audit record from the same instrument.

TemperatureHumidityCold chainExcursion alertsAudit trail

Hardware: RTD / thermocouple sensors · logger · large temperature display.

HARDWARE

Sensors, loggers, interruptors and displays

Built like shop-floor equipment — rugged, configurable, and specified to the parameter, the channel count and the viewing distance you need.

KV2020 Series data logger

Data loggers — KV2020 Series

  • 1 to 64 channels — from a single panel logger to a full-plant record
  • Universal inputs: RTD, thermocouple, mV, mA, 4–20 mA, voltage and current
  • On-board memory, SD-card logging and periodic e-mail reports
  • Panel, DIN or wall mount; compact hide-anywhere and outdoor IP-rated variants
CP logger and current interruptor

CP loggers & current interruptors

  • Remote CP data logger at each test post — pipe-to-soil potential and current
  • Synchronised current interruptor (timer) for IR-free on/off potential surveys
  • GPS time synchronisation across the line; solar / battery option
  • Reports to the cloud for continuous, unattended monitoring

Sensors

  • Air quality: PM2.5, PM10, CO2, NO2, SO2, CO, temperature, humidity, wind
  • Stack / emission gas and flow; ambient dust (SPM / RSPM)
  • Temperature & humidity: RTD, thermocouple, digital T/H probes
  • IP-rated enclosures for outdoor, boundary and stack mounting

Displays — any size, indoor or outdoor

Large LED boards sized to the throw distance, showing live values, parameter names and units. Range, size, viewing distance and environment:

PANEL SIZEBEST FORVIEWING DISTANCEINDOOR / OUTDOORWEATHER RATING
2 × 3 ftControl room, gate lobby, indoor locationup to ~20 mIndoorStandard enclosure
3 × 4 ftShop floor, boundary wallup to ~40 mIndoor / coveredSplash-resistant
4 × 6 ftPublic / gate AQI board, outdoor boundaryup to ~70 mOutdoorIP-rated, weatherproof, sunlight-readable
CustomBuilt to your parameter list & viewing distanceTo specificationIndoor or outdoorTo specification

Digit height, brightness and number of parameter rows are configured to the size and the reading distance. Outdoor boards are sunlight-readable and IP-rated for rain and dust.

AQI board 4x6 ft outdoor
AQI board — 4×6 ft outdoor.
Emission-gas parameter board
Emission-gas parameter board.
Temperature and humidity board
Temperature & humidity board.
Alarm buzzer and beacon lamp

Alarms & buzzers

  • Audible buzzer and tower / beacon lamp on threshold breach
  • Relay outputs to drive sirens, gates or plant equipment
  • Wired alongside the logger — local warning without waiting for the cloud

EDITIONS & SOFTWARE

Basic, Advanced, Premium — set in software, not in the box

Every solution ships in three editions. They are software feature-gates, so a site can start on Basic and move up without changing the instrument on the wall.

BASIC

See it and log it

Continuous logging, a live display and configurable local alarms, with e-mail alerts on a breach. The proof starts the day it is installed.

ADVANCED

Report it and prove it

Adds the web dashboard, automatic compliance reports (daily, shift and exceedance), trend analytics and role-based login — the reporting and accountability layer.

PREMIUM

Connect it and scale it

Adds the cloud, multi-site roll-up, ERP / SCADA integration, the public display board and a live feed to the authority, with long retention and a full audit trail.

CAPABILITYBASICADVANCEDPREMIUM
Continuous logging & local display✓✓✓
Configurable thresholds & local alarm✓✓✓
E-mail alerts✓✓✓
SMS / WhatsApp alerts (at provider cost)OPTOPTOPT
Web dashboard–✓✓
Automatic compliance reports (Excel / PDF)–✓✓
Report types — daily, shift, exceedance, statutory–✓✓
Trend & exceedance analytics–✓✓
Login levelsSingleRole-basedRole-based + escalation
Cloud — minute data, 24×7–OPT✓
Multi-site / multi-location––✓
ERP / SCADA integration (API)–OPT✓
Public display board & live authority feed–OPT✓
Long retention & full audit trail–✓✓

✓ included   OPT optional add-on   – not in this edition.

Connectivity, integration & access

🔌
Connectivity & protocols

RS232 / RS485 (Modbus RTU), Modbus TCP / Ethernet, 4–20 mA, Wi-Fi, GPRS / 4G, USB and SD.

⇆
Works with your ERP

Feeds your existing ERP, SCADA or the authority portal by REST API or scheduled export — no rip-and-replace.

⚙
Configurable thresholds

High/low limits per parameter are configuration, not code, and change without a site visit.

🔒
Login levels & escalation

Operator, supervisor and admin roles; alerts escalate through defined levels if a breach is not addressed in time.

Alerts, plainly. E-mail alerts are included in every edition. SMS and WhatsApp use a third-party gateway, so those messages carry a per-message charge payable to the messaging provider — the software adds no markup.

OPTIONS & PRICING

Available in several options — take the part you need

Every solution is available as hardware, as compliance software, or as the whole integrated cloud. Each upgrades cleanly into the next, because the hardware and software are built together.

OPTION 01

Hardware

  • Sensors, loggers, CP interruptors and displays
  • Configurable thresholds and local alarms on the device
  • Standard protocols — wire it into your own system
  • Local logging and reports without any subscription

For plants that run their own SCADA / historian and just need reliable instruments.

OPTION 02

Compliance software

  • Runs on KVAR devices or the instruments you already have
  • Automatic compliance reports and exceedance alerts
  • Role-based login and timed escalation
  • On-premise or cloud; export to Excel, PDF, ERP or authority portal

For sites that have the sensors but need the reporting and accountability layer.

OPTION 03

Integrated cloud

  • The whole chain connected — devices to dashboard to report
  • Minute data to the cloud, 24×7, across every site
  • Public display board and live API feed to the authority
  • Long retention and a full audit trail

For mandated and multi-site programmes that need continuous, verifiable monitoring.

Indicative price ranges

Price depends on the option and the features selected — channels, parameters, display size and range, number of users and login levels, and the edition. Indicative starting ranges:

LOGGERS

₹8K – 45K

Per logger, by channel count, input types and connectivity.

DISPLAYS

₹12K onwards

By panel size, digit height, range and indoor / outdoor build.

SOFTWARE

Basic from ₹3L

By users, login levels, sites and edition (Basic / Advanced / Premium).

Sensors, CP interruptors, alarms and installation are quoted to the site. Figures are indicative starting points for budgeting; a firm quotation is prepared against your requirement.

Return on investment

The system pays for itself the first time it keeps you compliant — and every day it saves the manual work of proving it.

Avoid penalties — a missed exceedance can mean a fine, a notice or a shutdown; continuous proof keeps you clear.
Pass audits without the scramble — the compliance report is already written and time-stamped.
End manual logging — no registers, no transcription, no gaps for an inspector to question.
Catch drift early — an alert before a reading becomes a violation, while you can still act.
Reuse what you have — the software runs on existing instruments; no rip-and-replace.
One supplier — sensor to report, one team accountable, one number to call.

From a reading on a sensor — to a report you can hand to the inspector.

KVAR Technologies environmental compliance range. Parameters, sensors, editions and display sizes are configured to the application; prices are indicative starting ranges for budgeting and are refined at proposal stage. Product photographs shown where available; remaining items to be added. Contact KVAR Technologies for a configuration and quotation matched to your site.

NEXT STEP

From the sensor to the signed report

  1. Tell us the parameter, the limits and whether it is for a regulator, a customer or your own record
  2. We specify sensors, logger, display and edition — and a report format the authority will accept
  3. Start with hardware or the full integrated cloud — and scale across sites when you are ready
Send an Enquiry →
KVAR Technologies Pvt. Ltd. 68, Kakad Industrial Estate, L.J. Cross Road No.3, Mahim (W), Mumbai — 400 016
Phone: 022 6899 0651-52  ·  7506 059922  ·  Email: sales@kvartech.com
www.kvartech.com  ·  Future-ready. Today.
✉ Enquire